Flame Seal FX950

Flame Seal FX950 is a water-based Intumescent paint that can be applied to most substrates including, lumber, plywood, OSB, and Gypsum. FX950 is fully tested and has a rating ranging from Class A to 2 hours to meet building codes domestically, internationally, and for the Wildfire Urban Interface. When Flame Seal FX950 is exposed to fire or extreme heat, a protective layer of Carbon Foam develops and prevents the fire and heat from transferring to the substrate. FX950 is a low VOC fire retardant paint with a smooth white architectural grade finish. This product can be paired with a primer and a top-coat. For best application Flame Seal recommends using an airless sprayer, please see the application guide for more information.

Category:

Description

Flame Seal FX950 is a low-VOC, water-based intumescent fire resistive material (IFRM) for use on lumber, plywood, OSB, Gypsum and other building materials. When FX950 is exposed to fire or extreme heat, a protective layer of carbon char develops and prevents fire and heat from transferring to the substrate. FX950 has a wide range of certifications to meet building codes domestically, internationally, and for the Wildfire Urban Interface. FX950 has a standard white architectual-grade finish.


Introduction

Flame Seal FX950 is a water-based Intumescent paint that can be applied to most substrates including, lumber, plywood, OSB, and Gypsum. FX950 is fully tested and has a rating ranging from Class A to 2 hours to meet building codes domestically, internationally, and for the Wildfire Urban Interface. When Flame Seal FX950 is exposed to fire or extreme heat, a protective layer of Carbon Foam develops and prevents the fire and heat from transferring to the substrate. FX950 is a low VOC fire retardant paint with a smooth white architectural grade finish. This product can be paired with a primer and a top-coat. For best application Flame Seal recommends using an airless sprayer, please see the application guide for more information.


Flame Seal FX950 Documentation


TestingĀ 

Substrate Test Standard Result WFT DFT Coverage Rate sq ft/gal
Wood ASTM E 84 Class A 9 6 180
Wood CAN/ULC S102 Class A 9 6 180
Wood ASTM 2768 Pass 20 13 80
Gypsum ASTM E119 2 Hours 60 40 27
Gypsum CAN/ULC S101 2 Hours 60 40 27


Primer & Top Coating

Primers and top coats may be required in high humidty applications or when a desired color is needed. The use of primers and top coats have been tested to the ASTM E-84 and ASTM 2768. Testing data shows that the use of top coats have no affect on the burn performance of Flame Seal FX950. For a list of recommended primers and top coats please email marketing@egispro.com